The translation on this website may be generated by machine translation. The quality and accuracy of machine translation can vary significantly from one text to another. Read the page in original English here.
Find the types of export destinations and settings available in Connexion client.
When you click Create in the Options Export tab, you select the destination type and then enter settings appropriate to the type you selected, as shown in the following table.
If you select this export destination type...
In this window, enter these settings...
File
In the Export Filename window, select a file or type of file name (e.g., export.dat) in the File Name box.
Note: By default the destination name contains the path name X:\Program Files\OCLC\Connexion\Program\, where X is the letter of your hard drive. You are not required to have the path name as part of the file name.
LPT Port
In the Export LPT Settings window:
Select the LPT (parallel) port you want to use.
LPT1
LPT2
LPT3
Select the type of translation your local system vendor requires. For most sessions, this value is None.
Value
Transfers
Does not transfer
Translates
Does not translate
None
All data
Nothing
All
OCLC M105
All data
Special characters
Diacritics
7 Bit
Only 7-bit data
Diacritics
Special characters
Start-of-message indicator
End-of-message indicator
Subfield delimiter
8 Bit
All data
Start-of-message indicator
End-of-message indicator
Subfield delimiter
Diacritics
Special characters
Click OK.
Connection
(Serial, network, or TCP/IP communications connection)
In the Export Connection Settings window, select the type of translation your local system vendor requires. For most sessions, this value is None.
Value
Transfers
Does not transfer
Translates
Does not translate
None
All data
Nothing
All
OCLC M105
All data
Special characters
Diacritics
7 Bit
Only 7-bit data
Diacritics
Special characters
Start-of-message indicator
End-of-message indicator
Subfield delimiter
8 Bit
All data
Start-of-message indicator
End-of-message indicator
Subfield delimiter
Diacritics
Special characters
Click Create.
In the New Communication Connection window, select Asynchronous or TCP/IP.
In the Asynchronous Settings window, accept the default or change settings for port, baud rate, parity, data bits, stop bits, and flow control.
In the TCP/IP Settings window, enter the name of the host system to which you export. Change other options if needed.
When you create a TCP/IP Connection for the first time, you may not be able to complete the process. After you enter your TCP/IP settings and click OK, the client adds the destination name to the list in the Export Connection Settings window. If the OK button is unavailable (grayed out), to complete adding your destination:
Double-click the name of your destination in the Export Connection Settings window. The Export Destination Name window opens showing your destination name prefixed by Connection:.
Click OK. The client adds the destination to the list in the Options Export tab.
OCLC Gateway Export
In the OCLC Gateway Export - Local System Settings window, enter or select the settings required for your local system:
Enter host name and port
Select local options for exporting
Enter timeout (minutes), number of retries, and delay (minutes)